UPS…

Jun 25 02:24:15 +02:00 xerox apcupsd: [daemon.crit] Power failure.
Jun 25 02:24:16 +02:00 xerox apcupsd: [daemon.alert] User logins prohibited
Jun 25 02:24:22 +02:00 xerox apcupsd: [daemon.crit] Running on UPS batteries.

Jun 25 04:12:31 +02:00 xerox apcupsd: [daemon.crit] Power failure.
Jun 25 04:12:32 +02:00 xerox apcupsd: [daemon.alert] User logins prohibited
Jun 25 04:12:37 +02:00 xerox apcupsd: [daemon.crit] Running on UPS batteries.
Jun 25 04:12:37 +02:00 xerox apcupsd: [daemon.crit] Mains returned. No longer on UPS batteries.
Jun 25 04:12:37 +02:00 xerox apcupsd: [daemon.alert] Power is back. UPS running on mains.
Jun 25 04:12:37 +02:00 xerox apcupsd: [daemon.alert] Allowing logins

– højst et par minutter senere slukkede UPSen helt umotiveret og uvarslet 👿 . Da jeg tændte den igen, ved 7-tiden, viste den overspændingsfejl og USB-porten var død. Ved hjælp af serielporten fik jeg udlæst data fra den – 271 V på forsyningssiden, påstod den. Et voltmeter viste 232 V. Den viste også for høj batterispænding og så tog jeg den altså fra.

Nu må jeg se, om jeg kan få indboforsikringen til at dække den.

Sårbarhed i WPS-protokollen på trådløse routere

Skidt nyt til indehavere af trådløse netværk af nyere dato – Så nemt bryder man ind i beskyttede trådløse netværk.

Måske også for os andre: “Reaver er ikke kun i stand til at finde WPS-pinkoden, men kan også knække kodeordet til WPA/WPA2 i løbet af 4-10 timer. Hermed er der fuld adgang til routeren.” Knække WPA/WPA2 i løbet af 10 timer? Det lyder usandsynligt, men hvis det er sandt er det virkeligt skidt!

Hvis du har en trådløs router og anvender WPA/WPA2, så benyt følgende side til at generere en “Maximum WPA Security (63 characters/504 bits)” key – og gem den på en USB-nøgle, så du kan flytte den til besøgendes maskiner:

WPA encryption Key Generator

– og så skal du selvfølgelig slå WPS fra. Kig i manualen eller Google routernavn og -model og find en vejledning.

Hvis din router kun understøtter WEP skal du straks aflevere den på genbrugsstationen 😈

Årets energiregnskab – 2011

Brændstof-regnskab:

  • 1013,48 liter diesel (862,14 liter i 2010)
  • 10226,78 kroner (7576,50 kroner i 2010)
  • 15384 kilometer (11420 kilometer i 2010)
  • gennemsnit: 10,09 kroner per liter og 15,2 kilometer per liter (8,79 kroner per liter og 13,2 kilometer per liter i 2010)

Jeg har fået lidt længere på arbejde og kommer nu rent faktisk en del ud til kunder. Alligevel overrasker det mig lidt, at jeg har kørt så meget længere i år. Det er dog stadig under de 20.000 km om året som vi havde forventet, da vi valgte at købe en dieselbil.

El-forbrug:

  • 6393 kWh (6207 kWh i 2010)
  • uge-gennemsnit: 123 kWh

Det stiger bare, uanset hvad jeg gør 👿


Vand-forbrug:

  • 155,6 m3 (148,8 m3 i 2010)
  • uge-gennemsnit: 3,0 m3


Naturgas-forbrug:

  • 1818,11 m3 (2161,74 m3 i 2010)
  • uge-gennemsnit: 34,96 m3

Det ses, at 2011 var noget varmere end 2010, selvom 2011 startede med mange måneders frost.

Årets energiregnskab – 2010

Årets energiregnskab – 2009

Årets energiregnskab – 2008

Sorry QNAP – my bad

For 1½ years I have been telling QNAP, that their interface counters were wrong, when queried with SNMP, at least on a TS-419P. It was off by strange factor, that didn’t really fit with anything.

Then today I noticed the command cmdwatch (watch in Linux) and I did a

cmdwatch -n5 snmpget -v 2c -c secretstring qnapnas IF-MIB::ifInOctets.4

Then I saw it, of course. The counter was fluxuating  up and down. Silly me. 😳 I had upgraded all my network equipment to gigabit speed, but I had missed the fact, that a 32 bit counter will wrap within the 5 minute intervals of MRTG querying.

So I had to Google how to query 64 bit counters in MRTG and it was pretty simple, just append :::::2 to the Target line.

I have written to QNAP support and offered them my apology :mrgreen:

Afmontering af pedaler

Så stod jeg lige der og skulle have afmonteret nogen cykelpedaler, så den gamle reservecykel ikke fyldte så meget. Og der er jo noget med pedaler, så meget kunne jeg huske fra min ungdom – en af siderne har links-gevind og skal altså løsnes modsat af normalen. Men hvilken side var det nu?

Her kommer internettet til sine fulde ret – det tog ikke mange øjeblikke at finde denne fine side: Park Tool: Repair Help and Education

Links er jo tysk og betyder venstre og det er netop venstre pedal, der har links-gevind, mens højre pedal har det normale højregevind. Der er dog flere gode huskeregler – for eksempel fandt jeg en der skrev, at når man strammer pedalerne bliver kæden stram. En anden var mere pragmatisk – hvis det ikke virker den ene vej, så prøv den anden! Jeg vil nok anbefale en af de to første.


Nogen der mangler 30-pins RAM?

Nogen der har en gammel 80×386 eller 486, de mangler noget RAM til? I min garageoprydning er jeg stødt på 12 styk 1 MB 30-pins SIMM-moduler – i alt 12 MB RAM! Det var meget, dengang 🙂 Og der kunne kun sidde 8 styk i èn maskine.

Men vent, der er mere – jeg fandt også 8 styk 4 MB 30-pins SIMM-moduler – i alt 32 MB RAM – det var rigtigt meget RAM. Sandsynligvis har det siddet i en DTP-maskine på Ugebladet Ingeniøren, en gang i starten af halvfemserne.

Jeg har intet at bruge dem til selv, men hvis nogen historie-interesserede kan bruge dem, så er de til afhentning.

30-pins SIMM

Til venstre ses 8 x 4MB SIMM, til højre ses 12 x 1 MB SIMM